CHINT mcb elcb DZ158LE-100 2P 80A 100A Residual current Circuit breaker RCBO
motor protection circuit breaker Size:111*78*80mm
mcb elcb
Personnel and fire protection,Cable and line protection against overload and short -circuits
mcb elcb Operated Circuit Breaker with over-current protection (Electronic)
General rules for choosing RCBO:
Rated residual operating current In 30 mA: additional protection in the case of direct
contact In 300 mA: preventative fire protection in the case
of ground fault currents
b.Tripping class AC class Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase.
c.Tripping curve
C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.
D curve (10-14 In) protection and control of the circuits against overloads and short-circuits; protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers, breakdown lamps).
residual current circuit breaker SPEC:
Standard |
IEC/EN 60947-2 |
||
Electrical features |
Type (wave form of the earth leakage sensed) |
AC |
|
Thermo-magnetic release characteristic |
8-12In |
||
Rated current In |
A |
63,80,100 |
|
Rated voltage Ue |
V |
230/400 |
|
Rated sensitivity In |
A |
0.03, 0.1, 0.3 |
|
Rated residual making and breaking capacity Im |
A |
2,000 |
|
Rated short-circuit capacity lcn |
A |
6,000 |
|
Break time under In |
s |
0.1 |
|
Rated frequency |
Hz |
50 |
|
Rated impulse withstand voltage (1.2/50)Uimp |
V |
4,000 |
|
Dielectric TEST voltage at ind. Freq. for 1min |
kV |
2 |
|
Insulation voltage Ui |
500 |
||
Pollution degree |
3 |
||
Mechanical features |
Electrical life |
1,500 |
|
Mechanical life |
8,500 |
||
Contact position indicator |
Yes |
||
Protection degree |
IP20 |
||
Ambient temperature (with daily average35C) |
C |
-5...+40 (Special application please refer to P68 for temperature compensation correction) |
|
Storage temperature |
C |
-25...+70 |
|
Installation |
Terminal connection type |
Cable/Pin-type busbar |
|
Terminal size top/bottom for cable |
mm2 |
16-50 |
|
AWG |
6-1/0 |
||
Terminal size top/bottom for busbar |
mm2 |
16-35 |
|
AWG |
6-2 |
||
Tightening torque |
N*m |
3.5 |
|
In-Ibs. |
31 |
||
Mounting |
On DIN rail EN 60715 (35mm) by means of fast clip device |
||
Connection |
From top |
mcb elcb Temperature derating
Rated current In (A) |
Temperaturecompensation coefficient under various operational temperature |
|||||||
-10 |
0 |
10 |
20 |
30 |
40 |
50 |
60 |
|
63 |
1.275 |
1.215 |
1.15 |
1.075 |
1.00 1.00 1.00 |
0.915 |
0.825 |
0.735 |
80 |
1.27 |
1.205 |
1.135 |
1.27 |
0.925 |
0.845 |
0.755 |
|
100 |
1.275 |
1.21 |
1.135 |
1.075 |
0.925 |
0.845 |
0.755 |